Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Rxn-10 probe body: 6061 aluminum, 316L stainless steel, and 303 stainless steel
Designed for product and process development, the Rxn-10 probe is the workhorse of the Raman probe portfolio. It is trusted to deliver high performance Raman measurements across a wide spectral range. It is also compact, lightweight, and flexible, offering multi-purpose convenience for solids and liquids analysis in the laboratory environment. The Rxn-10 probe accepts a variety of interchangeable optics, making it a highly versatile and easily adaptable instrument in your laboratory toolbox.
Chemical: reaction monitoring, blending, catalysis, hydrocarbon speciation, process unit optimization
Polymer: polymerization reaction monitoring, extrusion monitoring, polymer blending
Pharmaceutical: API reaction monitoring, crystallization
Biopharmaceutical: monitoring, optimization, and control of cell culture, fermentation, and downstream applications
Food & Beverage: zonal heterogeneity mapping of meats and fish
Multipurpose use for both solids and liquids measurement
Lightweight and compact
Integrated laser safety interlock, including “laser on” indication and probe shutter
Flexible output compatible with a range of sampling options
Easy switching of non-contact, immersion, and bioprocessing optics to suit a variety of applications
Wide spectral range, including access to the critical low-wavenumber region
Felső kategóriás termékek
Műszaki kiválóság
Egyszerűség
Egyszerű termékek
Műszaki kiválóság
Egyszerűség
Alaptermékek
Műszaki kiválóság
Egyszerűség
Felső kategóriás termékek
Műszaki kiválóság
Egyszerűség
Speciális termékek
Műszaki kiválóság
Egyszerűség
Kombinálható
FLEX választék | Műszaki kiválóság | Egyszerűség |
---|---|---|
Fundamental választék Eleget tesz az Ön alapvető mérési igényeinek |
Műszaki kiválóság
|
Egyszerűség
|
Lean választék Könnyen kezeli az Ön alapvető folyamatait |
Műszaki kiválóság
|
Egyszerűség
|
Extended választék Innovatív technológiákkal optimalizálja az Ön folyamatait |
Műszaki kiválóság
|
Egyszerűség
|
Xpert választék Megoldás az Ön legnagyobb kihívást jelentő alkalmazásaihoz |
Műszaki kiválóság
|
Egyszerűség
Kombinálható |
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | HU | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Nyelv: |
Angol |
Változat: |
31/05/2023 |
Fájlméret: |
467.9 KB |
Fájlnév: |
TI01635CEN_0322.pdf |
System design and specifications
for the Raman Rxn-10 probe
Nyelv: |
Angol |
Változat: |
31/05/2023 |
Fájlméret: |
423 KB |
Fájlnév: |
TI01629CEN_0322.pdf |
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
EN | HU | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Nyelv: |
Angol |
Változat: |
31/05/2023 |
Fájlméret: |
1.8 MB |
Fájlnév: |
BA02171CEN_0322.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
Nyelv: |
Angol |
Változat: |
31/05/2023 |
Fájlméret: |
1.2 MB |
Fájlnév: |
BA02160CEN_0322.pdf |
Quick start guide for the Raman Rxn-10 probe
Nyelv: |
Angol |
Változat: |
31/05/2023 |
Fájlméret: |
895.3 KB |
Fájlnév: |
KA01546CEN_0322.pdf |
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
EN | HU | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Nyelv: |
Angol |
Változat: |
31/05/2023 |
Fájlméret: |
1 MB |
Fájlnév: |
KA01551CEN_0322.pdf |
An overview of Raman spectroscopy analyzer systems (including the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe, and Rxn-45
probe), powered by Kaiser Raman technology, for fermentation
compositional analysis in a lab or process applicable to biotechnology
in the food & beverage industry.
Nyelv: |
Angol |
Változat: |
03/03/2022 |
Fájlméret: |
603 KB |
Fájlnév: |
PU01457CEN_0122.pdf |
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).
Nyelv: |
Angol |
Változat: |
19/04/2022 |
Fájlméret: |
1.1 MB |
Fájlnév: |
PU01447CEN_0222.pdf |
An overview of the Raman flow assembly (flow bench and flow cell)
used with the Rxn-10 probe in conjunction with a Raman Rxn2
analyzer and a Raman flow assembly calibration and verification kit
for downstream bioprocessing (powered by Kaiser Raman technology).
Nyelv: |
Angol |
Változat: |
31/05/2023 |
Fájlméret: |
837 KB |
Fájlnév: |
PU01517CEN_0123.pdf |
An overview of the Raman calibration and verification kits for
the bio multi optic / single use optic and the Raman flow assembly
(includes the flow bench and flow cell). These kits are to be used in
conjunction with the Rxn-10 probe and Raman Rxn2 / Rxn4 analyzer
for upstream and downstream bioprocessing (powered by Kaiser
Raman technology).
Nyelv: |
Angol |
Változat: |
13/12/2023 |
Fájlméret: |
2.1 MB |
Fájlnév: |
PU01518CEN_0223.pdf |