Radar measurement
Time-of-Flight
Micropilot FMR56

Micropilot FMR56 aluminum housing ©Endress+Hauser
Micropilot FMR56 plastic housing ©Endress+Hauser

Time-of-Flight measuring principle

Commissioning movie for Micropilot FMR5x free space radar and Levelflex FMP5x guided radar

Unique HistoROM data management concept for safe level measurement

Continuous adapting algorithms offering safe level measurement due to Multi-Echo Tracking

Economically efficient basis model for level measurement in solids

Micropilot FMR56 is particularly designed for light-duty process conditions as they occur in silos or bins for solids. Micropilot free space radar is used for continuous,
non-contact level measurement in powdery to granular bulk solids. Dust, filling noises, temperature layers and gas layers do not affect the measurement.

  • Előnyök

    • Reliable measurement even for changing product and process conditions

    • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

    • Highest reliability even in the presence of obstructions in the vessel due to new Multi-...

  • Alkalmazási terület

    PP-plated horn antenna can be easily aligned to the surface of the solids by the mounting bracket or a turnable seal.

    • Process connections: Mounting bracket or slip-on flange

    • Temperature: -40 to +80°C (-40 to +176°F)

    • Pressure: -1 to +3bar (-14.5 to +43....

Tulajdonságok és jellemzők

Vissza

Details

  • Mérési elv

    Level radar solid

  • Characteristic / Application

    For simple applications:
    Reliable non-contact level measurements in silos or storage tanks for bulk solids

  • Specialities

    Heartbeat Technology,

    Bluetooth® commissioning,

    Operation and maintenance SmartBlue App,

    Safety and reliability with Multi- Echo Tracking,

    HistoROM,

    RFID TAG for easy identification,

  • Supply / Communication

    2-wire (HART/ PROFIBUS PA/ FOUNDATION Fieldbus)

    4-wire (HART)

    Bluetooth® wireless technology and App (optional)

  • Frequency

    K-band (~26 GHz)

  • Antenna

    Horn DN80/3", PP plated

    Horn DN100/4", PP plated

  • Accuracy

    +/- 3 mm (0.12 in)

  • Ambient temperature

    -40 °C...+80 °C

    (-40 °F...+176 °F)

  • Process temperature

    -40 °C...+80 °C

    (-40 °F...+176 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum...3 bar

    (Vacuum...43.5 psi)

  • Main wetted parts

    PP, UP

  • Process connection

    Flange:

    UNI DN80...DN150
    (3"...6")

    Mounting bracket

  • Max. measurement distance

    30 m (98 ft)

  • Communication

    4...20 mA HART

    PROFIBUS PA

    FOUNDATION Fieldbus

    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, KC

  • Safety approvals

    SIL

  • Options

    Display,

    Customized parameterization

    Remote operation via SmartBlue App using Bluetooth®

  • Application limits

    DK < 1.6

    Reduction of the max. possible measuring range through:

    Media with poor reflection properties

    Angle of repose

    Extremely loose surfaces of bulk solids, e.g. bulk solids with low bulk weight for pneumatic filling

    Build-up, above all of moist products

Dokumentumok / Kézikönyvek / Szoftver

Tartozékok / alkatrészek

Nr
Order code
Specification
  • 19
    • Nr 19 Order code 71115175

      Housing filter Brass/Ni GT19/20, 1 set

      Consists of: 2x filter plug brass nickel, pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 17
    • Nr 17 Order code 71115176

      Set housing securing clamps

      Usage: housing GT18/GT19/GT20, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 20
    • Nr 20 Order code 71110292

      Cover GT19 PBT, sight glass, EPDM

      Material: plastics PBT-FR sight glas PC. O-ring EPDM, PTFE coated. Usage: FHX50, FMP50/FMP51/FMP52/ FMP53/FMP54/FMP55/FMP56/FMP57, FMR50/ FMR51/FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

    • Nr 20 Order code 71110293

      Cover GT19 PBT, EPDM

      Material: plastics PBT, metallized. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

    • Nr 20 Order code 71110297

      Cover GT20 Alu, sight glass, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 20 Order code 71110299

      Cover GT20 Alu, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 25
    • Nr 25 Order code 71110295

      Cover GT19 PBT, Terminal Ex, EPDM

      Material: plastics PBT, metallized. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

    • Nr 25 Order code 71110301

      Cover GT20 Alu, Terminal Ex, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71110302

      Cover GT20 Alu, Terminal Ex d, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71185517

      Cover GT20 Alu, Terminal, OVP, HNBR

      Material: aluminium. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71185518

      Cover GT19 PBT, Terminal, OVP, EPDM

      Material: plastic PBT, metallizied. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

  • 65
    • Nr 65 Order code 71110303

      Sealing set GT18/GT19/GT20, EPDM, HNBR

      Consists of: O-ring 88.5x3.53 EPDM/PTFE, cover electronics compartment, housing GT19. O-Ring 88.5x3.53 NBR, cover electronics compartment, housing GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, cover terminal compartment, housing GT19. O-Ring 91.67x3.53 NBR, cover terminal compartment, housing GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, housing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 71128617

      Overvoltage protection (OVP10),1-Channel

      4-20mA HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 71128619

      Overvoltage protection (OVP20),2-Channel

      4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 34
    • Nr 34 Order code 71108594

      I/O module 2-wire, 4-20mA, HART, Ex, V2

      Non-Ex, Ex. 1x current output HART. Version 2. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57.

    • Nr 34 Order code 71108599

      I/O module, 2-wr.,4-20mA,HART,PFS,Ex,V1

      Non-Ex, Ex. 1x current output HART, 1x PFS. PFS=switch output. Version 1. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57. FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57.

    • Nr 34 Order code 71164940

      I/O module, 2-wire, PA/FF, PFS, Ex, V2

      Non-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS=switch output. Version 2. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass 200, Prowirl 200, Promag 200.

    • Nr 34 Order code 71187812

      I/O mod.Level,2-wr.4-20mA,HART,Ex,LP,V2

      Version 2. Not for Ex d/XP. LP=low powered. 1x current output HART. Usage: FMP50/FMP51/FMP52/FMP53/FMP54/ FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/ FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

    • Nr 34 Order code 71207473

      I/O mod. Level,4-wr.DC,4-20mA,HART,Ex,V2

      Non-Ex, Ex. 10.4-48VDC. 1x current output HART. Version 2. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

    • Nr 34 Order code 71207474

      I/O mod. Level, 2-wr.2x4-20mA,HART,Ex,V2

      Non-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Version 2. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57.

    • Nr 34 Order code 71207475

      I/O mod. Level,4-wr.AC,4-20mA,HART,Ex,V2

      Non-Ex, Ex. 90-253VAC. 1x current output HART. Version 2. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

  • 37
    • Nr 37 Order code 71110279

      Terminal set 4-wire, I/O module

      Consists of: 2x terminal 2-pole, green. 2x terminal 2-pole, red. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

    • Nr 37 Order code 71110280

      Terminal set 2-wire, I/O module

      Consists of: 4x terminal 2-pole, green. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 30
  • 40
    • Nr 40 Order code XPD0024-

      Display module, SD02, push buttons

      For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.

    • Nr 40 Order code XPD0025-

      Display module, SD03, Touch Control

      For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.