Levelflex M FMP41C
Ez a termék már nem elérhető.
Az új generációról az előd / utód szakaszban találhat tájékoztatást vagy forduljon a helyi Endress+Hauser képviselethez.
Dokumentumok / Kézikönyvek / Szoftver
-
Levelflex M FMP41C, FMP45
Technical Information
Guided Level-Radar
Continuous Level Transmitter for
'- Level Measurement in Liquids
'- Interface Measurement in LiquidsMűszaki leírás (TI) -
Weld-in adapter, process adapter and flanges
Level and pressure measurement
Műszaki leírás (TI) -
Levelflex M FMP41C
HART
Operating Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in liquids.Használati utasítás (BA/KA) -
Levelflex M FMP40, FMP41C, FMP43, FMP45
HART, PA, FF
Description of Instrument Functions
Smart Transmitter for continuous
level measurement in liquidsHasználati utasítás (BA/KA) -
Levelflex M FMP40, FMP41C, FMP45
Measurement
Guided Level Radar for Interface Measurement with HART
Használati utasítás (BA/KA) -
Levelflex M FMP41C
PROFIBUS PA
Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in liquids.Használati utasítás (BA/KA) -
Levelflex / Levelflex M
Zentrierscheibe / Centering disk (PFA)
Mounting Instructions
Accessory
Használati utasítás (BA/KA) -
Levelflex M FMP41C
FOUNDATION Fieldbus
Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in liquids.Használati utasítás (BA/KA) -
Levelflex M FMP41C
Interface measurement
Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for interface measurement in liquids.Használati utasítás (BA/KA) -
Levelflex M FMP41C
PROFIBUS PA
Brief Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in liquids.Short Instruction (KA)11/10Angol -
Levelflex M FMP41C
HART
Brief Operating Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in liquids.Short Instruction (KA)11/10Angol -
Levelflex M FMP41C
FOUNDATION Fieldbus
Brief
Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in liquids.Short Instruction (KA)11/10Angol -
Levelflex M FMP41C
Interface measurement
Brief
Operating Instructions
Instructions
Guided Level-Radar
Continuous Level Transmitter for level measurement in liquids.Short Instruction (KA)11/10Angol -
Weather protection cover
Mounting Instruction
Weather protection cover for devices with F12/T12/F23 housing.
Short Instruction (KA)06/07Német , Angol , Spanyol , fr , Olasz , Holland -
Exchange of probe rod/rope on Levelflex M FMP41C
Exchange of probe rod/rope on Levelflex M FMP41C
Short Instruction (KA)04/12Német , Angol -
Exchange of probe with process connection on Levelflex M FMP40,
FMP41C
Exchange of probe with process connection on Levelflex M FMP40,
FMP41CShort Instruction (KA)04/12Német , Angol -
Levelflex M FMP40, FMP41C, FMP45
HART, PROFIBUS PA, FOUNDATION Fieldbus
Leveflex M Kurzanleitung/Brief operating instructions
HART, PROFIBUS PA, FOUNDATION FieldbusShort Instruction (KA)04/09Német , Angol -
Levelflex M FMP40, FMP41C, FMP43, FMP45
HART, PROFIBUS PA, FOUNDATION Fieldbus
Leveflex M Kurzanleitung/Brief operating instructions
HART, PROFIBUS PA, FOUNDATION FieldbusShort Instruction (KA)03/07Német , Angol -
Electronic module (Interface measurement)
Installation instruction
Levelflex M, FMP40, FMP41C, FMP43, FMP45
Szerelési útmutató (EA) -
Electronics for Levelflex M
Installation instruction
Levelflex M
Szerelési útmutató (EA) -
Cable separate version
Installation Instructions
Cerabar M, Cerabar S, Deltabar S, Deltapilot M, Deltapilot S
Szerelési útmutató (EA) -
Terminal module for housing F12/F23
Installation Instruction
Micropilot M, Levelflex M, Prosonic M
Szerelési útmutató (EA) -
Cover F23
Installation instruction
Levelflex M, Micropilot M
Szerelési útmutató (EA) -
HF module
Installation instruction
Levelflex M
Szerelési útmutató (EA) -
Levelflex M FMP41C
KEMA 04 ATEX 1129 X
ATEX II 1/2 G, II 2 G, II 1/2 D, II 1/3 D, II 3 D
Protection:
Ex ia IIC T6...T1, Ex tD Axx IP68Robbanásvédelmi előírások (XA) -
Safety Instructions
Levelflex M FMP41C
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex nA IIC T6...T1 Gc
GYJ12.1453X (NEPSI)Robbanásvédelmi előírások (XA) -
Safety Instructions
Levelflex M FMP41C
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex d ia [ia Ga] IIC T6...T1 Ga/Gb
GYJ12.1261X (NEPSI)Robbanásvédelmi előírások (XA) -
Safety Instructions
Levelflex M FMP41C
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex emb [ia] IIC T6...T1
GYJ101291 (NEPSI)Robbanásvédelmi előírások (XA) -
Levelflex M FMP41C
KEMA 04 ATEX 1129 X
ATEX II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1Robbanásvédelmi előírások (XA) -
Safety Instructions
Levelflex M FMP41C
4-20 mA HART
Ex ia IIC T6...T1
GYJ111018 (NEPSI)Robbanásvédelmi előírások (XA) -
Levelflex M FMP41C
KEMA 04 ATEX 1129 X
ATEX II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1Robbanásvédelmi előírások (XA) -
Levelflex M FMP41C
KEMA 04 ATEX 1129 X
ATEX II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1Robbanásvédelmi előírások (XA) -
Safety Instructions
Micropilot M, Levelflex M, Prosonic M
FM Control Drawing
EMC C-module for ToF apparatus
Cl. I, II, III, Div. 2, Group A, B, C, D, E, F, G
and Cl. I, Zone 2, Group IIC
NIFW installationRobbanásvédelmi előírások (XA) -
Levelflex M FMP41C
KEMA 04 ATEX 1129 X
ATEX II 2 G
Protection: Ex e mb [ia] IIC T6...T1Robbanásvédelmi előírások (XA) -
Safety Instructions
Levelflex M FMP41C
PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIC T6...T1
GYJ111018 (NEPSI)Robbanásvédelmi előírások (XA) -
Levelflex M FMP41C
KEMA 04 ATEX 1129 X
ATEX II 1/2 D, II 2 D, II 1/3 D
Protection: Ex tD Axx IP68Robbanásvédelmi előírások (XA) -
Levelflex M FMP41C
KEMA 04 ATEX 1129 X
ATEX II 1/2 G, II 2 G
Protection: Ex d [ia] IIC T6...T1Robbanásvédelmi előírások (XA) -
Levelflex M FMP41C
KEMA 04 ATEX 1129 X
ATEX II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1Robbanásvédelmi előírások (XA) -
Levelflex M FMP41C
KEMA 04 ATEX 1129 X
ATEX II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1Robbanásvédelmi előírások (XA) -
Levelflex M FMP41C
KEMA 04 ATEX 1129 X
ATEX II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1Robbanásvédelmi előírások (XA) -
Levelflex M FMP41C
KEMA 04 ATEX 1129 X
ATEX II 1/2 G, II 2 G, II 1/2 D, II 1/3 D, II 3 D
Protection: Ex ia IIC T6...T1, Ex tD Axx IP68Robbanásvédelmi előírások (XA) -
Levelflex M FMP41C
EG 05 016-a
ATEX II 3 G Protection: EEx nA II T6...T1 X
HART, PROFIBUS PA; Foundation FieldbusRobbanásvédelmi előírások (XA) -
Levelflex M FMP41C
KEMA 04 ATEX 1129 X
ATEX II 1/2 G, II 2 G, II 1/2 D, II 1/3 D, II 3 D
Protection:
Ex ia IIC T6...T1, Ex tD Axx IP68Robbanásvédelmi előírások (XA) -
Levelflex M FMP40, FMP41C, FMP45
Allgemeine bauaufsichtliche Zulassung
Z-65.16.354Bizonylat (ZE) -
Levelflex M FMP41C
HART
FM
Drawing No.: 960414-1064 A Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
IS-HART
FM
Drawing No.: 960414-1066 A Drawing Type: Installation drawingBizonylat FM/CSA (ZD) -
Grounding of screen variations
Screen grounding
Bizonylat FM/CSA (ZD) -
Levelflex M FMP41C
PROFIBUS PA, FOUNDATION Fieldbus
FM
Drawing No.: 960414-1070 A, 960414-1071 A Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
IS-HART
FM
Drawing No.: 960414-1069 A Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
IS-HART
CSA
Drawing No.: 960414-2069 A Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
PROFIBUS PA, FOUNDATION Fieldbus
FM
Drawing No.: 960414-1067 A, 960414-1068 A Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
CSA
Drawing No.: 960414-2063 ADrawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
IS-HART
FM
Drawing No.: 960414-1061 A Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
PROFIBUS PA, FOUNDATION Fieldbus
CSA
Drawing No.: 960414-2067 A, 960414-2068 A Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
IS-HART
CSA
Drawing No.: 960414-2066 A Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
PROFIBUS PA, FOUNDATION Fieldbus
CSA
Drawing No.: 960414-2062 A, 960414-2065 A Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
PROFIBUS PA, FOUNDATION Fieldbus
FM
Drawing No.: 960414-1062 A, 960414-1065 A Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
FM
Drawing No.: 960414-1063 A Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
CSA
Drawing No.: 960414-2063 B Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
HART
CSA
Drawing No.: 960414-2064 A Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
PROFIBUS PA, FOUNDATION Fieldbus
CSA
Drawing No.: 960414-2070 A, 960414-2071 A Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP41C
IS-HART
CSA
Drawing No.: 960414-2061 A Drawing Type: Control drawingBizonylat FM/CSA (ZD) -
Levelflex M FMP40, FMP41C, FMP43, FMP45
Functional Safety Manual
Guided level-radar for liquids and bulk solids
Speciális dokumentáció (SD) -
Levelflex M FMP40, FMP41C, FMP43, FMP45
Micropilot M FMR230, FMR231, FMR240, FMR244, FMR245, FMR250
Hinweis zur Montage
Füllstand-Radar für Flüssigkeiten und Schüttgütern
Geführtes Füllstand-Radar für Flüssigkeiten und SchüttgüterSpeciális dokumentáció (SD) -
Tie-on label
Tie-on label
Speciális dokumentáció (SD) -
Levelflex M FMP40, FMP41C, FMP43, FMP45
Functional Safety data sheet / Datenblatt zur Funktionalen Sicherheit
Speciális dokumentáció (SD) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Információ a gyártóról (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Információ a gyártóról (MI) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Információ a gyártóról (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Információ a gyártóról (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Információ a gyártóról (MI) -
Levelflex M FMP40, FMP41C, FMP45
Manufacturer Information for users regarding software updates(NE53)
Software version V01.04.00 HART / PROFIBUS PA
Információ a gyártóról (MI) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Információ a gyártóról (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Információ a gyártóról (MI) -
Manufacturer information for users regarding software updates (NE53)
Manufacturer information for users regarding software updates (NE53)
Információ a gyártóról (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Információ a gyártóról (MI) -
Napędy i Sterowanie styczeń 2008
Modernizacja pływakowych lub nurnikowych pomiarów poziomu
Publikációk (PU)08/09Lengyel -
Przetworniki poziomu Levelflex NiS_02_2011
Nowa rodzina innowacyjnych radarów falowodowych Levelflex
Evolution SeriesPublikációk (PU)04/12Lengyel -
Nap&
281;dy i Sterowanie kwiecie&
324; 2007
Detekcja ko&
324;ca sondy
w radarach falowodowychPublikációk (PU)04/07Lengyel -
Przetworniki poziomu - art CE 04/2011
Przetworniki poziomu
Jednoczesne wytwarzanie ciepła i energii elektrycznej, czyli kogeneracja
to w ostatnich latach niezwykle popularne zagadnienie w polskiej
energetyce cieplnej i zawodowej. Pozwala ona na obniżenie poziomu
zużycia węgla w procesie wytwarzania energii. Ograniczenie emisji do
atmosfery szkodliwych gazów oraz zmniejszenie strat energii między
wytwórcą i odbiorcą.
Składowanie biomasy w elektrociepłowni lub w elektrowni.
Pomiary ilości biomasy w silosach magazynowych.Publikációk (PU)03/12Lengyel -
CS0429F Remote hygienic guided radar increases filling speed and
decreases down
time
Levelflex M FMP41C with great success in level measurement involving
foam. Fluctuations in the density. temperature, or build-up donot
influence the measurement.Esettanulmányok06/10Angol -
Guided radar technology copes with the difficult terms of a bioreactor
The Levelflex M FMP41C is used for continuous level measurement of
liquids andh as the highest chemical resistance.Esettanulmányok06/10Angol -
Guided radar Levelflex M used in milk processing
Levelflex M in milk processing, FMP41C in liquid applications
Esettanulmányok01/10Angol -
Levelflex M Guided Level-Radar via PROFIBUS PA o the PlantPAx Process
Automation System
System using a 1788HP-EN2PA Linking Device
Integration DocumentRendszerépítő partner05/09Angol -
Levelflex M Guided Level-Radar via HART to the PlantPAx Process
Automation System
System using a ControlLogix 1756 HART Analog Input Module
Integration DocumentRendszerépítő partner01/09Angol -
GSD Single, GSD_EH_PA_LE_Levelflex_0x152D_V01_00_PALIB, 14.04.2014 (Level
, Levelflex M, 0x152D)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, PDM_PA_LE_LevelflexM_0x152D_0x02_0x01, 07.01.2019 (Level, Levelflex M, 0x152D)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_LevelflexM_0x1012_0x04_0x01_FFLIB_ITK4_61, 09.11.201
6 (Level, Levelflex M, 0x1
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.61Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_LevelflexM_0x1012_0x04_0x03_FFLIB_ITK5_20, 09.11.201
6 (Level, Levelflex M, 0x1
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.20Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_LevelflexFMP4x_0x0012_0x02_0x02, 01.10.2015 (Level, Levelflex M)
HART,
PDM Version: 6.0 SP5, 6.1, 8.1, 8.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_LE_LevelflexM_0x152D_0x04_0x01, 07.01.2019 (Level, Levelflex M, 0x152D)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_LevelflexM_0x1012_0x04_0x02_FFLIB_ITK5_00, 09.11.201
6 (Level, Levelflex M, 0x1
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.00Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_LevelflexM_0x1012_0x03_0x03_FFLIB_ITK4_60, 09.11.201
6 (Level, Levelflex M, 0x1
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.60Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_LevelflexM_0x1012_0x03_0x01_FFLIB_ITK4_01, 09.11.201
6 (Level, Levelflex M, 0x1
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.01Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_LevelflexM_0x0020_0x08_0x08, 07.11.2018 (Level, Levelflex M, 0x0020)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_LevelflexFMP4x_0x0012_0x04_0x05, 01.10.2015 (Level, Levelflex M)
HART,
PDM Version: 6.0 SP5, 6.1, 8.1, 8.1 SP1, 8.2Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, LevelflexM_FMP4x_FF_V4_xx_DevRev4, 08.07.2019 (Level, Levelflex M, 0x1012)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, LevelflexM_FMP4x_PA_V2_06, 09.07.2019 (Level, Levelflex M, 0x152D)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, LevelflexM_FMP4x_PA_V2_00___2_02, 08.07.2019 (Level, Levelflex M, 0x152D)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, LevelflexM_FMP4x_PA_V2_04, 08.07.2019 (Level, Levelflex M, 0x152D)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, LevelflexM_FMP4x_PA_V4_xx, 09.07.2019 (Level, Levelflex M, 0x152D)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, LevelflexM_FMP40_V2_00, 08.07.2019 (Level, Levelflex M, 0x0012)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, LevelflexM_FMP4x_V4_xx, 08.07.2019 (Level, Levelflex M, 0x0012)
HART,
DeviceCare Version: 1.06.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, LevelflexMInt_FMP4xI_V1_08, 08.07.2019 (Level, Levelflex M, 0x0020)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_FF_Package_Level_1_05_00, 29.05.2018 (Level)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02, R3.12Faceplate1.05.00Language neutral -
Prosonic S, Nivector, Micropilot, LIQUITREND, Liquipoint, Liquiphant M, Liquicap M, Levelflex, Deltapilot S, Deltapilot M, Deltabar S, Deltabar, Ceraphant, Cerabar T, Cerabar S, Cerabar M, Cerabar
Termékkód: FTI52-, FTL33-, FTL330H-, FTL330L-, FTL50H-, FTL51H-, FTW23-, FTW33-, OTL330H-, OTP35-, PMC51-, PMC71-, PMP135-, PMP23-, PMP51-, PMP55-, PMP75-, PTP33B-, QMW43-, FDL60-, FDL61-, FDU91F-, FMB50-, FMB70-, FMD71-, FMD72-, FMD78-, FMI51-, FMI52-, FMP41C-, FMP43-, FMP52-, FMP53-, FMR245-, FMR52-, FMR62-, FTI26-, FTI51-
Régió: USA
Tanúsító szervezet: 3-A Sanitary StandardsHygienic EquipmentAngol -
Product Family: Levelflex M
Termékkód: FMP45-, FMP41C-, FMP40-
Régió: International
Tanúsító szervezet: PI, PROFIBUS International
Software Version: PROFILE 3.0Fieldbus ConformanceAngol -
Product Family: Levelflex M
Termékkód: FMP40-, FMP45-, FMP41C-, FMP43-
Régió: International
Tanúsító szervezet: Fieldbus Foundation
Software Version: DEVICE REV. 04, DD-ITK 5.20Fieldbus ConformanceAngol
Tartozékok / alkatrészek
-
-
Order code 52006628
Instrument plug M20-M12 "PA" (WDM)150
4-pin metall plug for installation in the device, providing connection to a T-Box (WDM) or cable socket (WDM). Cable length: 150mm. Not suitable for PROMAG and PROMAG.
-
-
-
Nr 12 Order code 535720-9020
Set of screws housing F12/T12/F23
Consists of: 1x stop screw M5x10. 1x retaining screw M8x10. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.
-
-
-
Order code 543199-0001
Protective cover for housing T12/F12, SS
Usage: Micropilot M, Micropilot S, Prosonic M, Levelflex M. Material: 316Ti.
-
-
-
Nr 20 Order code 517391-0011
Cover F12/T12 Alu, coated, gasket
Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.
-
Nr 20 Order code 52005936
Cover F12/T12 Alu, window, gasket
Material: aluminium. Usage: VU331, housing F12/T12, Micropilot M/S, Prosonic M, Levelflex M.
-
Nr 20 Order code 52018670
Cover F23 316L, sight glass, gasket
Material: 316L. Usage: VU331, Levelflex M, Micropilot M.
-
Nr 20 Order code 52018671
Cover F23 316L, gasket
Material: 316L. Usage: Levelflex M, Micropilot M.
-
-
-
Nr 25 Order code 518710-0020
Cover T3/T12 Alu, coated, gasket
Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231,FMR240/FMR244/ FMR245, FMR250, FMR530/FMR531/FMR532/ FMR533, FMR540, FMU40/FMU41/FMU42.
-
-
-
Nr 11 Order code 52006026
Cover terminal compartment F12/F23
Hood terminal compartment. Usage: Micropilot M, Prosonic M, Levelflex M.
-
Nr 11 Order code 52019062
Cover terminal compartment F12/F23,FHX40
Hood terminal compartment. Usage: separate display, Micropilot M, Prosonic M, Levelflex M.
-
-
-
Nr 35 Order code 52006197
Terminal module 4-pole, HART, 2-wire
Cable connection. Usage: housing F12/F23, Micropilot M, Levelflex M, Prosonic M.
-
Nr 35 Order code 52012156
Terminal module 4-pole, PA, FF
PROFIBUS PA, FOUNDATION Fieldbus. Usage: Micropilot II/M, Prosonic M, Levelflex M.
-
Nr 35 Order code 52013302
Terminal mod. Ex d, 4-pol., 2wr,HART,T12
Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.
-
Nr 35 Order code 52013303
Terminal mod. Ex d, 2-pol.,2wr,PA/FF,T12
2-wire, PROFIBUS PA/FOUNDATION Fieldbus. Ex d limiter. Usage: housing T12, Levelflex M, Micropilot M, Prosonic M.
-
Nr 35 Order code 52018949
Terminal mod. 4-pol.,EEx ia,HART,T12,OVP
4-pole, 2-wire. OVP = overvoltage protection. Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.
-
Nr 35 Order code 52018950
Terminal mod. 2-p.,EEx ia,PA/FF,T12,OVP
2-pole, 2-wire. PROFIBUS PA, FOUNDATION Fieldbus. OVP = overvoltage protection. Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.
-
-
-
Nr 11 Order code 52005643
Hood housing T12
Cable compartment, electronics side. Usage: Micropilot M/S, Prosonic M, Levelflex M.
-
-
-
Nr 35 Order code 52013304
Power supply 10.5-32VDC (housing F12)
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
Nr 35 Order code 52013305
Power supply 90-250VAC (housing F12)
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
Nr 35 Order code 52015585
Power supply CSA, 10.5-32VDC (housg F12)
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
Nr 35 Order code 52015586
Power supply CSA, 90-250VAC (housg F12)
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
-
-
Nr 40 Order code 52026443
Display VU331, version 2
Alphanumeric display, 4-line. Usage: FMR530/532/533, FMR540, FMU40/41/42/43/44.
-
-
-
Order code 52013874
-
Order code FHX40-
Display FHX40
Remote display + local operation. 4-line LC-display. :: Menu driven plain text operation. :: Easy setup. :: User language selectable. :: Envelope curve display on site. Usage: FMG60, FMU40/FMU41/FMU42/FMU43/FMU44.
-
Order code 52023572
Profile gasket silicone, 5 pieces
Process gasket universal process adapt. FDA listed. Usage: FMB50, FMB70, FMI51/FMI52, FTI51/FTI52/FTI55, PMC51.
-
Order code 52018204
Adaption kit housing F12, 2-wire, FHX40
Modification to remote display. Housing F12, 2-wire electronics. Non-hazardous area only. Please order FHX40 separately. Usage: Micropilot II/M, Prosonic M, Levelflex M.
-
Order code 52018205
Adaption kit housing F12, 4-wire, FHX40
Modification to remote display. Housing F12, 4-wire electronics. Non-hazardous area only. Please order FHX40 separately. Usage: Levelflex M, Prosonic M.
-
Order code 52016334
Cable FHX40, 20m
Connection cable, doubled shielded. Usage: FHX40.
-
Order code 71020502
Cable FHX40, 5m
Connection cable, doubled shielded. Usage: FHX40.
-
Order code 71020503
Cable FHX40, 10m
Connection cable, doubled shielded. Usage: FHX40.
-
Order code 71020504
Cable FHX40, 30m
Connection cable, doubled shielded. Usage: FHX40.
-
Order code 71007843
ToF Adapter FXA291
Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.
-
Order code 71000221
Adapterk. FMR2xx,FMx4x,PMx7x,FMD7x,FMG60
Connection service tool RS232(52013675)/ ToF adapter FXA291 (71007843). Usage: FMG60, FMD77/FMD78, FMR230/ FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44, NRF590, PMC71, PMD75, PMP71/PMP75.
-
Order code 71006590
HF-test cable 6GHz
Coax cable. Usage: FMR230/FMR231, FMR530/FMR531/FMR532/FMR533, FMR540. Dummy antenna.
-
Order code 52028063
HF-test cable 6GHz + resistor
Coax cable. Termination resistor / connection piece. Usage: FMR530/FMR532/FMR533, FMR540. Dummy antenna.
-
Order code 52010173
Weld-in adapter UNI D85, 316L, 3.1
Flush mount process connection. Core hole: 85mm. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52, PMC51, PMP23, PMP55, PMP75.
-
Order code 52010174
Weld-in adapter UNI D65, 316L, 3.1
Flush mount process connection. Core hole: 65mm. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52, PMC51, PMP23, PMP55, PMP75.
-
Order code 71063562
HART Loop Converter HMX50
Consists of: 1x HART input (intrinsically safe). 3x 4-20mA current output. 2x programmable SPDT relays. Menue guided operation. Nominal supply voltage 24VDC. Usage: FMM20.
-
Order code 71069065
Centering star PFA 37mm/16mm
Spacers for rods 16mm/0.63in. Tmax 250oC/482oF. Material: PFA. FDA, EG1935/2004, EU10/2011 compliant. Usage: FMP51/FMP52/FMP54/FMP55.
-
Order code
Phase out spares
-
Order code
-
-
Utód