Level measurement, capacitive. Application: liquids. Fully insulated rod probe. Additional safety feature. Suitable at heavy process condition. Housing, separate terminal chamber. :: High pressure / high temperature :: Suitable at heavy stress from side :: Longtime stable tightness
Fully insulated rod probe for high pressure and high temperature, suitable for heavy process condition A: North America Certificate (IS,XP) S: Additional safety feature
Specialities
Foam detection
Supply / Communication
PFM
Ambient temperature
Standard: -40 °F ... 160 °F With separate housing: -80oF ... 280 °F
Process temperature
-110 °F ... 390 °F
Process pressure / max. overpressure limit
Vacuum ... 1450 psi
Main wetted parts
Insulation material: PTFE, PFA, FEP 316TI
Process connection
NPT1 1/2" Flange from DN50.../ASME 2".../JIS...
Process connection hygienic
Tri-Clamp ISO2852
Sensor length
4 inch ... 240 inch Inactive length metal: 4 inch ... 160 inch Inactive length fully insulated: 4 inch ... 80 inch
Communication
PFM
Certificates / Approvals
FM CSA
Options
Separate housing (HTC), Inactive length, Active build-up compensation
Components
Transmitter PFM: FTC325, FTC625, FTC470Z, FTC471Z
Successor
FTI51
Application limits
Notice the pressure and temperature derating. Notice for non conductive medium the DK.
Characteristic / Application
Fully insulated rod probe for high pressure and high temperature, suitable for heavy process condition A: North America Certificate (IS,XP) S: Additional safety feature
Specialities
Foam detection
Supply / Communication
HART PROFIBUS PA PFM
Linearity error for conductive liquids
< 1% at 40 inch
Ambient temperature
Standard: -40 °F ... 160 °F With separate housing: -80oF ... 280 °F
Process temperature
-110 °F ... 390 °F
Process pressure / max. overpressure limit
Vacuum ... 1450 psi
Main wetted parts
Insulation material: PTFE, PFA, FEP 316TI
Process connection
NPT1 1/2" Flange ab DN50.../ASME 2".../JIS...
Process connection hygienic
Tri-Clamp ISO2852
Sensor length
4 inch ... 240 inch Inactive length metal: 4 inch ... 160 inch Inactive length fully insulated: 4 inch ... 80 inch
Max. measurement distance
4 inch ... 160 inch ( 4 m )
Communication
HART PROFIBUS PA PFM
Certificates / Approvals
FM CSA
Options
Separate housing (HTC), Inactive length
Components
Transmitter PFM: FMX570, FMC671Z, FMC661
Successor
FMI51
Application limits
Notice the pressure and temperature derating. Notice for non conductive medium the DK.