RTD-Assembly S.A. Style TLSR1

Product picture resistance thermometer TLSR1 ©Endress+Hauser

Ez a termék már nem elérhető.

Az új generációról az előd / utód szakaszban találhat tájékoztatást vagy forduljon a helyi Endress+Hauser képviselethez.

Tulajdonságok és jellemzők

Vissza

Details

  • Mérési elv

    Resistance Temperature Detector

  • Characteristic / Application

    S.A. Style

    universal range of application

    usable with or without a thermowell

  • Terminal head

    wide range of heads possible

    possible materials of construction: PVC, aluminium, SS316

    mixed output options possible

  • Thermowell / protection tube

    to use with or without thermowell (can be ordered separately)

  • Insert / probe

    mineral insulated (MI), flexible

  • Max. immersion length on request

    up to 2.000 mm (78,74'')

  • Material protection tube/ thermowell

    1.4401 (316)

  • Optional coating

    Not defined

  • Process connection

    Fixed thread:

    NPT 1/4"

    NPT 1/2"

    G1/4"

    G1/2"

    Adjustable compression fitting:

    NPT 1/8"

    NPT 1/4"

    NPT 3/8"

    NPT 1/2"

    G1/8"

    G1/4"

    G3/8"

    G1/2"

  • Tip shape

    rounded

    flat

  • Operating temperature range

    PT 100:

    -200 ...600 °C

    (-328 ...1.112 °F)

  • Max. process pressure (static)

    at 20 °C: 10 bar (150 psi) without thermowell

  • Accuracy

    class A according to IEC 60751

    Band 5 (1/10 DIN)

  • Response time

    depending on configuration

  • Integration head transmitter

    yes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Certification

    EN10204 3.1 Material traceability

Dokumentumok / Kézikönyvek / Szoftver

Tartozékok / alkatrészek

Nr
Order code
Specification
    • Order code 71044061

      Fixing kit cpl.TMT82/85/84 (european)

      2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector

    • Order code TMT180-

      iTEMP TMT180, Head Transmitter Pt100

      Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

  • B
    • Nr B Order code TID10-

      Display for head transmitter TID10

      to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82.

  • Utód