HAW562
Surge arrester

HAW562 surge arrester ©Endress+Hauser
HAW562 surge arrester ©Endress+Hauser
HAW562 surge arrester ©Endress+Hauser
HAW562 surge arrester ©Endress+Hauser

Surge arrester for DIN rail according to IEC 60715

The HAW562 surge arrester is used to protect electronic components from being destroyed by overvoltage. It ensures that overvoltage surges which occur in signal cables (e.g. 4 to 20 mA), in communication lines (fieldbuses) and in power lines are safely passed into the ground. The functionality of the transmitter or the electronics component to be protected is not affected.

  • Előnyök

    • Investment intensive measuring instruments protected

    • Increased plant availability as surge arrester is perfectly matched to the electronic components involved in process automation and process measuring technology

    • Application in Ex areas - optionally...

  • Alkalmazási terület

    Surge arresters are used to weaken residual currents from upstream lightning protection steps and to limit system-induced or -generated overvoltage surges.

    HAW562 units are primarily used in process automation and in measuring and communication...

Tulajdonságok és jellemzők

Vissza

Details

  • Mérési elv

    Surge arrester

  • Measuring principle

    Surge arrester for DIN rail mounting

  • Function

    Surge arresters are applied to protect electronic components of a plant against overvoltage! Due to this investment intensive measuring instruments are protected and the plant availability is increased.

  • Application

    Surge protection for power supply or signal / communication cables

  • SIL

    2

  • Certificates

    ATEX

    IECEx

    CSA

  • Mérési elv

    Surge arrester

  • Function

    Surge arrester for DIN rail mounting

    Compact device for an easy ordering (no separation of mounting module and protection module)

    Flexible integration into the measuring chains of the process industry due to approvals according to ATEX & IEC, SIL2 conformity

    compatibility with the established fieldbusses (HART, FF, PA)

    Innovative grounding concept to avoid low-frequency equalizing currents – direct and indirect shield grounding possible in one device

    Uninterruptible operation of the plant due to an automatic resetting after the discharge process

  • Certification

    SIL2 conformity


    CSA

  • Dimensions (wxhxd)

    HAW562-AAA, HAW562-AAD, HAW562-AAE, HAW562-8DA:

    12 x 90 x 72.5 mm

    (0.47" x 3.54" x 2.85")


    HAW562-AAB, HAW562-AAC:

    18 x 90 x 73 mm

    (0.71" x 3.54" x 2.87")

  • Operating Voltage

    24V/60V/230V/5V/12(80)V/24V

Dokumentumok / Kézikönyvek / Szoftver

Tartozékok / alkatrészek

Nr
Order code
Specification