iTHERM TM411
Innovative advanced, modular RTD thermometer

iTHERM TM411
Innovative advanced, modular RTD thermometer ©Endress+Hauser
iTHERM TM411
Innovative advanced, modular RTD thermometer ©Endress+Hauser

For use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries

It has been designed to meet the requirements of the Food & Beverages and Life Sciences industries and complies with the highest quality standards. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. It offers many technical innovations: iTHERM QuickSens, StrongSens or QuickNeck. This leads to distinctive reduction of maintenance costs, improved product quality, process efficiency and safety.

  • Előnyök

    • User-friendly and reliable from product selection to maintenance

    • iTHERM inserts: globally unique, fully-automated production. Full traceability and consistently high product quality for reliable measured values

    • iTHERM QuickSens: fastest response times (...

  • Alkalmazási terület

    • Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries

    • Measuring range: –200 to +600 °C (–28 to +1 112 °F)

    • Pressure range up to 40 bar (580 psi)

    • Protection class: up to IP69K

Tulajdonságok és jellemzők

Vissza

Details

  • Mérési elv

    Resistance Temperature Detector

  • Characteristic / Application

    metric style

    modular temperature assembly

    hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)

    hygienic process connections

    with neck

    suitable for hazardous areas

    incl. protection tube

    QuickSens for fastest response time

    StrongSens for most robust design

    QuickNeck for easy and cost saving recalibration

  • Terminal head

    TA30A - E+H, aluminium - cover low, hinged - w. or w/o. display

    TA30D - E+H, aluminium - cover high, hinged

    TA30R - stainless steel blasted - screwed cover - w. or w/o. display

    TA30R - stainless steel handpolished - screwed cover - w. or w/o.
    display

    TA30S - polypropylene - screwed cover

    TA30P - polyamide - cover high, hinged

  • Thermowell / protection tube

    without

    incl. thermowell

    incl. T-/ellbow thermowell

  • Insert / probe

    mineral insulated (MI), flexible

    pipe version, isolated wires, not flexible

  • Outer diameter protection tube / Insert

    6,0 mm (0,24")

    9,0 mm (0,35")

    12,7 mm (0,5")

  • Material protection tube/ thermowell

    1.4435 delta-ferrit < 1%

    316L

  • Process connection

    compression fitting

    weld in adapter

    clamp connections acc. to ISO2852

    screwed pipe joint acc. to DIN 11851

    aseptic screwed pipe joint acc. to DIN 11864-1

    metallic sealing system

    thread acc. to ISO 228 for liquiphant adaptor

    APV Inline

    Varivent

    Ingold

    SMS 1147

    Neumo Biocontrol

    T- and corner pieces

  • Tip shape

    straight

    reduced

    tapered

  • Surface roughness Ra

    0,76 μm (29,92 μin)

    0,38 μm (14,96 μin)

    0,38 μm (14,96 μin) electropolished

  • Operating temperature range

    PT100:

    -200 °C … 600 °C

    (-328 °F … 1.112 °F)

    StrongSens:

    -50 °C … 500 °C

    (-58 °F … 932 °F)

    QuickSens:

    -50 °C … 200 °C

    (-58 °F … 392 °F)

  • Max. process pressure (static)

    at 20 °C: 40 bar (580 psi)

  • Accuracy

    class A acc. to IEC 60751

    class AA acc. to IEC 60751

  • Response time

    depending on configuration

    QuickSens: t90 = 1,5 s

    StrongSens: t90 = 9,5 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX II

    ATEX IECEx

    FM

    CSA

    NEPSI

    CRN

  • Certification

    SIL (transmitter only)

Dokumentumok / Kézikönyvek / Szoftver

Tartozékok / alkatrészek

Nr
Order code
Specification
  • A
    • Nr A Order code TA30A-

      Terminal Head TA30A

      Retainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).

    • Nr A Order code TA30R-

      Terminal Head TA30R

      Retainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temp.: -50...85/130 oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact desing and low weight.

    • Nr A Order code TA30S-

      Terminal Head TA30S

      Retainer for terminal block. or head transmitter. Cover: screwed. Material: Polypropylene. Colour: white. Ambient Temp.: -30...+130oC. Protection: IP65, NEMA4X (housing). :: easy wiring through good accessibility. :: compact desing, low weight.

  • B
    • Nr B Order code TMT180-

      iTEMP TMT180, Head Transmitter Pt100

      Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr B Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT71-

      iTEMP TMT71, Transmitter 4-20mA

      2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.

    • Order code TMT72-

      iTEMP TMT72, Transmitter HART

      2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC

  • B
    • Nr B Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr B Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr B Order code TID10-

      Display for head transmitter TID10

      to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82.

    • Nr B Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr B Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.

    • Order code FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

    • Order code READWIN-

      Readwin 2000 Operation + Read. software

    • Order code TXU10-

      Configuration kit TXU10-

      for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.

    • Order code TM411-

      iTHERM TM411

      Modular hygienic resistance thermometer. Metrical version with exch. insert for applications in the food/beverages and pharmaceutical industries. With or w/o thermowell. Measuring range: -200...+600oC / -328...1.112oF (depending on the configuration). ::Fastest response times for optimal process control through iTHERM QuickSens insert. ::Maximum robustness for highest process safety through iTHERM StrongSens insert. ::Cost savings with recalibrations through iTHERM QuickNeck coupling.