Conductive
Point level detection
One rod probe 11961Z

Probe 11961Z ©Endress+Hauser

High resistance point level detection of conductive liquids steam boilers and aggressive media

The 11961Z is a highly resistant probe for applications with aggressive medium thanks to corrosion-resistant materials for rod and insulation. It can be used in steam boilers thanks to ceramic insulation resistant to steam and hot water.

  • Előnyök

    • Safe and reliable measurement even in aggressive medium thanks to corrosion-resistant materials for rod and insulation

    • Can be used in steam boilers thanks to ceramic insulation resistant to steam and hot water

    • Can be deployed particularly with high...

  • Alkalmazási terület

    For conductive point level detection in process or storage tanks, for conductivity as of 0.02mS/cm. As overfill prevention with line monitoring even in Ex-area Zone 0, or pump protection in pipes and two-point control.

    • Process connection: Thread

    • ...

Tulajdonságok és jellemzők

Vissza

Details

  • Mérési elv

    Conductive

  • Characteristic / Application

    One rod probe for high and extremely low temperature and high pressure. Corrosion resistant

  • Supply / Communication

    Relay
    PFM

  • Ambient temperature

    -200 °C ... 250 °C
    (-328 °F ... 482 °F)

  • Process temperature

    -200 °C ... 250 °C
    (-328 °F ... 482 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum ... 160 bar
    (Vacuum ... 2320 psi)

  • Min. conductivity of medium

    20 µS/cm

  • Main wetted parts

    Ceramic, 316TI

  • Process connection

    G 1/2

  • Sensor length

    0.1m ... 2m
    (3.9" ... 79")

  • Communication

    Relay

  • Safety approvals

    Overfill prevention WHG

  • Components

    Transmitter: FTW325

  • Application limits

    Observe min. medium conductivity

Dokumentumok / Kézikönyvek / Szoftver

Tartozékok / alkatrészek

Nr
Order code
Specification
  • Előd