Omnigrad M TR46

Product picture of: Omnigrad M TR46

Ez a termék már nem elérhető.

Az új generációról az előd / utód szakaszban találhat tájékoztatást vagy forduljon a helyi Endress+Hauser képviselethez.

Tulajdonságok és jellemzők

Vissza

Details

  • Mérési elv

    Resistance Temperature Detector

  • Characteristic / Application

    metric style

    Inline-Thermometer

    hygienic design

    with neck

  • Terminal head

    TA20A - aluminium - cover with scews

    TA20B - plastics - screw cover

    TA20D - aluminium - hinged cover high

    TA20J - SS - deep-drawn w. or w/o. display

    TA20R - SS - machined w. screw cover

    TA20W - aluminium - cover w. snap fit

    TA21E - aluminium - screw cover w. chain

  • Thermowell / protection tube

    without (not intended to use with thermowell)

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    -

  • Max. immersion length on request

    -

  • Material protection tube/ thermowell

    1.4435 (316L)

  • Optional coating

    -

  • Process connection

    hygienic:

    clamp connections acc. to ISO 2852 / DIN 32676

    screwed pipe joint acc. to DIN 11851

    screwed pipe joint acc. to DIN 11864-1

  • Tip shape

    -

  • Surface roughness Ra

    0,4 μm (15,7 μin.)

    0,6 μm (23,6 μin.)

    0,8 μm (31,5 μin.)

  • Operating temperature range

    PT 100:

    -50 °C ...200 °C

    (-58 °F ... 392 °F)

  • Max. process pressure (static)

    at 20 °C: 40 bar (580 psi)

  • Accuracy

    class A acc. to IEC 60751

  • Response time

    -

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    -

  • Certification

    Gost Metrology

    FDA

    3A

    SIL (transmitter only)

Dokumentumok / Kézikönyvek / Szoftver

Tartozékok / alkatrészek

Nr
Order code
Specification
  • A
    • Nr A Order code TA20A-

      Terminal Head TA20A

      Product being phased out, limited availability. Connection head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material: Aluminium epoxy resin coating Area temperature : max. +100 oC; ATEX: +95 oC.

    • Nr A Order code TA20B-

      Terminal Head TA20B

      "Product being phased out, limited availability." Connecting head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material:Polyamid black. Ambient temperature: max. +80 oC. Protection: IP65.

    • Nr A Order code TA20D-

      Terminal head TA20D

      Product being phased out, limited availability. Connection head to mount a measuring insert with up to two head transmitters or a connection socket and one head transmitter. For mounting on armature or protection sleeve. Material: Aluminium, varnished Ambient temperature: max. +100 oC; ATEX: +95 oC. Protection: IP66

    • Nr A Order code TA20R-

      Terminal Head TA20R

      Product being phased out, limited availability. Connecting head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material: AISI316L/1.4404. max temperature 100oC, ATEX: +95oC. Protection class IP66/IP67.

    • Nr A Order code TA20W-

      Terminal head TA20W

      Product being phased out, limited availability. Connection head hinged to mount a measuring insert with head transmitter or connection socket. To be mounted on an armature or a protection sleeve. Material: Aluminium Area temperature: max. +100 oC; ATEX: +95 oC Protection: IP66

    • Nr A Order code TA21E-

      Terminal Head TA21E

      Retainer for terminal block or head transmitter. Cover: srewable. Material: aluminum. Max. temp.: +100 oC; ATEX +95 oC. Protection: IP65.

  • C
    • Nr C Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

  • C
    • Nr C Order code TMT180-

      iTEMP TMT180, Head Transmitter Pt100

      Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr C Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr C Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.