Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
785 nm
Body: 316L stainless steel
Window: optical-grade materials
ATEX, CSA, IECEx, UKCA, JPEx
For solids and semi-solids analysis, the Raman Rxn-20 probe reigns supreme. Its state-of-the-art, stainless-steel probe design produces representative, focus-free, quantitative Raman measurements. The Rxn-20 probe illuminates a large surface area and eliminates the need to align the probe for surface roughness. It provides heterogenous solids sampling via volumetric analysis, which is highly useful for measuring tablets, capsules, food solids, and polymer beads.
Chemicals: final product quality, blend impurities, crystallinity, raw materials
Polymers: extruded pellet quality, crystallinity, density, raw materials
Pharmaceutical: crystallinity, polymorphism, granulation, blend uniformity, content uniformity, coating, tableting
Food & Beverage: quality of dairy solids, meat and fish composition
Non-contact measurement of heterogeneous solids for better representation
Improved process control and efficiency through faster measurements
Non-destructive measurements from a distance
Reproducible sampling
Sampling flexibility with a variety of focus-free and immersion Rxn-20 accessory optics
No need to align probe for surface roughness
Surface and deep layer (volumetric) analysis
Felső kategóriás termékek
Műszaki kiválóság
Egyszerűség
Egyszerű termékek
Műszaki kiválóság
Egyszerűség
Alaptermékek
Műszaki kiválóság
Egyszerűség
Felső kategóriás termékek
Műszaki kiválóság
Egyszerűség
Speciális termékek
Műszaki kiválóság
Egyszerűség
Kombinálható
| FLEX választék | Műszaki kiválóság | Egyszerűség |
|---|---|---|
Fundamental választék Eleget tesz az Ön alapvető mérési igényeinek |
Műszaki kiválóság
|
Egyszerűség
|
Lean választék Könnyen kezeli az Ön alapvető folyamatait |
Műszaki kiválóság
|
Egyszerűség
|
Extended választék Innovatív technológiákkal optimalizálja az Ön folyamatait |
Műszaki kiválóság
|
Egyszerűség
|
Xpert választék Megoldás az Ön legnagyobb kihívást jelentő alkalmazásaihoz |
Műszaki kiválóság
|
Egyszerűség
Kombinálható |
System design and specifications for Rxn-20 probe accessories
| EN | HU | ||
|
03/08/2022
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
03/08/2022 |
|
Fájlméret: |
362.8 KB |
|
Fájlnév: |
TI01636CEN_0222.pdf |
System design and specifications for the Raman Rxn-20 probe
| EN | HU | ||
|
13/12/2024
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
13/12/2024 |
|
Fájlméret: |
670.1 KB |
|
Fájlnév: |
TI01631CEN_0323.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-20 probe
| EN | HU | ||
|
02/12/2024
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
02/12/2024 |
|
Fájlméret: |
1.5 MB |
|
Fájlnév: |
BA02167CEN_0323.pdf |
Commissioning, operation, and maintenance details
for Rxn-20 probe accessories
| EN | HU | ||
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
03/08/2022 |
|
Fájlméret: |
426.9 KB |
|
Fájlnév: |
BA02172CEN_0222.pdf |
Quick start guide for the Raman Rxn-20 probe
| EN | HU | ||
|
02/12/2024
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
02/12/2024 |
|
Fájlméret: |
752.2 KB |
|
Fájlnév: |
KA01547CEN_0323.pdf |
Quick start guide for Rxn-20 probe accessories
| EN | HU | ||
|
03/08/2022
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
03/08/2022 |
|
Fájlméret: |
377.8 KB |
|
Fájlnév: |
KA01552CEN_0222.pdf |
Hazardous area certifications and installation instructions
for the Raman Rxn-20 probe
| EN | HU | ||
|
21/06/2024
|
|
|
|
|
08/08/2023
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
21/06/2024 |
|
Fájlméret: |
893.6 KB |
|
Fájlnév: |
XA02747CEN_0424.pdf |
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).
|
Nyelv: |
Angol |
|
Változat: |
19/04/2022 |
|
Fájlméret: |
1.1 MB |
|
Fájlnév: |
PU01447CEN_0222.pdf |
A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
|
Nyelv: |
Angol |
|
Változat: |
26/06/2025 |
|
Fájlméret: |
363.4 KB |
|
Fájlnév: |
PU01611CEN_0125.pdf |
Ein Leitfaden zu unseren Anwendungshinweisen zur
Raman-Spektroskopie für die Life-Science-Industrie
(Raman Rxn2-Analysator, Raman Rxn4-Analysator,
Rxn-10-Sonde, Rxn-20-Sonde, Rxn-45-Sonde,
Rxn-46-Sonde und Zubehör für Sondenoptiken
(blO-Optic, Raman- Single Use-Optiksystem
/ SUB, Immersionsoptik, berührungslose Optik)
|
Nyelv: |
Német |
|
Változat: |
24/09/2025 |
|
Fájlméret: |
1.4 MB |
|
Fájlnév: |
PU01447CDE_0222_Raman-Anwendungsleitfaden_LSI_web.pdf |