Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Starter: 785 nm
Base Model: 532 nm, 785 nm, 1000 nm
Hybrid: 785 nm
Starter 785 nm: 300-3300 cm-1
Base model 532 nm: 150-4350 cm-1
Base model 785 nm: 150-3425 cm-1
Base model 1000 nm: 200-2400 cm-1
Hybrid 785 nm: 175-1890 cm-1
Adeptly harness the power of Raman spectroscopy with the Raman Rxn2 analyzer. Designed for use in analytical laboratories with model transfer capabilities, the Raman Rxn2 is heavily relied on for routine sample identification, support of R&D projects, early process development, and scale-up settings for in situ analysis. Available as a benchtop or on a mobile wheeled cart, the Raman Rxn2 offers location convenience and portability for process development laboratories.
Chemical: polymerization, extrusion monitoring, polymer blending, catalysis investigation
Pharmaceutical: reaction chemistry, yield crystallization, polymorph, blending, drying, granulations
Biopharmaceutical: bioprocess monitoring and control, PAT/QbD applications, cell culture, fermentation, downstream operations, cGLP/cGMP compatible
Food & Beverage: cultured meat, fermentation, oil or fat quality
Reliable real-time, in situ measurements
Intuitive, embedded control software via touchscreen or remote interface
Convenience of a single base unit supporting up to four probes
Sequential operation for fast analysis per channel and programmable channel interrogation
Converts acquired Raman spectra into process knowledge using built-in multivariate predictors
Suitable for outputs into hazardous area/classified environments
Proven model transferability to process development and manufacturing scales
Egyszerű termékek
Műszaki kiválóság
Egyszerűség
Alaptermékek
Műszaki kiválóság
Egyszerűség
Felső kategóriás termékek
Műszaki kiválóság
Egyszerűség
Speciális termékek
Műszaki kiválóság
Egyszerűség
Kombinálható
| FLEX választék | Műszaki kiválóság | Egyszerűség |
|---|---|---|
Fundamental választék Eleget tesz az Ön alapvető mérési igényeinek |
Műszaki kiválóság
|
Egyszerűség
|
Lean választék Könnyen kezeli az Ön alapvető folyamatait |
Műszaki kiválóság
|
Egyszerűség
|
Extended választék Innovatív technológiákkal optimalizálja az Ön folyamatait |
Műszaki kiválóság
|
Egyszerűség
|
Xpert választék Megoldás az Ön legnagyobb kihívást jelentő alkalmazásaihoz |
Műszaki kiválóság
|
Egyszerűség
Kombinálható |
System design and specifications for the Raman Rxn2 analyzer -
powered by Kaiser Raman technology
| EN | HU | ||
|
21/11/2023
|
|
|
|
|
01/09/2023
|
|
|
|
|
31/12/2020
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
21/11/2023 |
|
Fájlméret: |
1.2 MB |
|
Fájlnév: |
TI01608CEN_0323.pdf |
System information and specifications for the Raman data library 2.1
| EN | HU | ||
|
08/09/2025
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
08/09/2025 |
|
Fájlméret: |
191.3 KB |
|
Fájlnév: |
TI01869CEN_0125.pdf |
Commissioning, operation, and maintenance details
for Raman RunTime v6.6 software
| EN | HU | ||
|
27/03/2025
|
|
|
|
|
16/11/2023
|
|
|
|
|
30/06/2022
|
|
|
|
|
31/12/2020
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
27/03/2025 |
|
Fájlméret: |
6.8 MB |
|
Fájlnév: |
BA02180CEN_0525.pdf |
Instructions for administration of Raman data library 2.1 software
| EN | HU | ||
|
08/09/2025
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
08/09/2025 |
|
Fájlméret: |
1.2 MB |
|
Fájlnév: |
BA02564CEN_0125.pdf |
Instructions for use of Raman data library 2.1
| EN | HU | ||
|
08/09/2025
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
08/09/2025 |
|
Fájlméret: |
4.5 MB |
|
Fájlnév: |
BA02563CEN_0125.pdf |
Commissioning, operation, and maintenance details for the
Raman Rxn2 analyzer - powered by Kaiser Raman technology
| EN | HU | ||
|
21/03/2024
|
|
|
|
|
21/11/2023
|
|
|
|
|
01/08/2023
|
|
|
|
|
06/10/2022
|
|
|
|
|
31/12/2020
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
21/03/2024 |
|
Fájlméret: |
6.4 MB |
|
Fájlnév: |
BA02151CEN_0524.pdf |
Brief instructions and start-up instructions for Raman data library
software
| EN | HU | ||
|
13/08/2024
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
13/08/2024 |
|
Fájlméret: |
411.2 KB |
|
Fájlnév: |
KA01717CEN_0124.pdf |
Quick start guide for the Raman Rxn5 analyzer -
powered by Kaiser Raman technology
| EN | HU | ||
|
13/03/2025
|
|
|
|
|
16/01/2025
|
|
|
|
|
21/11/2023
|
|
|
|
|
31/12/2020
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
13/03/2025 |
|
Fájlméret: |
2.1 MB |
|
Fájlnév: |
KA01554CEN_0425.pdf |
Quick start guide for the Raman Rxn2 analyzer -
powered by Kaiser Raman technology
| EN | HU | ||
|
21/11/2023
|
|
|
|
|
01/09/2023
|
|
|
|
|
31/12/2020
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
21/11/2023 |
|
Fájlméret: |
2.5 MB |
|
Fájlnév: |
KA01544CEN_0323.pdf |
Hazardous area certifications and installation instructions
for the Raman Rxn2 analyzer - powered by Kaiser Raman technology
| EN | HU | ||
|
13/01/2025
|
|
|
|
|
07/12/2023
|
|
|
|
|
29/11/2022
|
|
|
|
|
31/12/2020
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
13/01/2025 |
|
Fájlméret: |
1.2 MB |
|
Fájlnév: |
XA02700CEN_0424.pdf |
A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
|
Nyelv: |
Angol |
|
Változat: |
26/06/2025 |
|
Fájlméret: |
363.4 KB |
|
Fájlnév: |
PU01611CEN_0125.pdf |
Graphic illustrating the core elements of Biopharma 4.0 including
product lifecycle stages, role of PAT/QbD, and 12 key advanced
technologies for scientists and process engineers in the Life
Sciences, applicable to Raman spectroscopy systems (Raman
Rxn2, Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and
sleeve, flow cell and flow bench, Raman optic system for single
use, and Raman calibration & verification kits).
|
Nyelv: |
Angol |
|
Változat: |
22/05/2025 |
|
Fájlméret: |
481.6 KB |
|
Fájlnév: |
PU01614CEN_0125.pdf |
An overview of the Raman flow assembly (flow bench and flow cell)
used with the Rxn-10 probe in conjunction with a Raman Rxn2
analyzer and a Raman flow assembly calibration and verification kit
for downstream bioprocessing (powered by Kaiser Raman technology).
|
Nyelv: |
Angol |
|
Változat: |
31/05/2023 |
|
Fájlméret: |
837 KB |
|
Fájlnév: |
PU01517CEN_0123.pdf |
Endress+Hauserが、ライフサイエンス分野の専門知識と、ラマン分
光システム(Raman Rxn2、Raman Rxn4、Rxn-10、Rxn-45、Rxn-46、
バイオマルチオプティックおよびスリーブ、フローフィル、フロー
ベンチ、シングルユース用Ramanオプティックシステム)や水質分
析センサ技術(Liquiline CM44P、CM442、OUSAF44、OUSBT66、
Memosens CPS61E、CLS82E、COS81E、CLS82E)などの信頼性の高い
インラインおよびリアルタイム測定技術によって、世界トップクラ
スのバイオ医薬品メーカーから信頼されている理由を強調したグラ
フィック。
|
Nyelv: |
Japán |
|
Változat: |
04/10/2024 |
|
Fájlméret: |
2.5 MB |
|
Fájlnév: |
PU01585CJA_0124_Graphic_EH biopharma trust.pdf |
この製品リストは、ライフサイエンス業界におけるバイオプロセス
用途向けに、光学分析および液体分析の両方から提供される分析機
器をまとめたものです。含まれる製品には、Raman Rxn2アナライザ
、Raman Rxn4アナライザ、Rxn-10プローブ、バイオマルチオプティ
ックおよびバイオスリーブ、ラマンフローアセンブリ、Rxn-45プロ
ーブ、Rxn-46プローブ、シングルユース向けラマンオプティックシ
ステム、Memosens CPS61E、Memosens COS81E、OUSBT66、Memosens
CPS77E、Memosens CLS82E、OUSAF44、Memosens CPS11E、Memosens
CLS16E、TOCアナライザーCA79、Liquiline変換器プラットフォーム
、およびMemobaseソフトウェアが含まれています。
|
Nyelv: |
Japán |
|
Változat: |
24/08/2025 |
|
Fájlméret: |
1.2 MB |
|
Fájlnév: |
PU01484CJA_0224_Lab-to-Process Control in Life Sciences.pdf |
Ein Leitfaden zu unseren Anwendungshinweisen zur
Raman-Spektroskopie für die Life-Science-Industrie
(Raman Rxn2-Analysator, Raman Rxn4-Analysator,
Rxn-10-Sonde, Rxn-20-Sonde, Rxn-45-Sonde,
Rxn-46-Sonde und Zubehör für Sondenoptiken
(blO-Optic, Raman- Single Use-Optiksystem
/ SUB, Immersionsoptik, berührungslose Optik)
|
Nyelv: |
Német |
|
Változat: |
24/09/2025 |
|
Fájlméret: |
1.4 MB |
|
Fájlnév: |
PU01447CDE_0222_Raman-Anwendungsleitfaden_LSI_web.pdf |
An overview of Raman spectroscopy analyzer systems (including the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe, and Rxn-45
probe), powered by Kaiser Raman technology, for fermentation
compositional analysis in a lab or process applicable to biotechnology
in the food & beverage industry.
|
Nyelv: |
Angol |
|
Változat: |
03/03/2022 |
|
Fájlméret: |
603 KB |
|
Fájlnév: |
PU01457CEN_0122.pdf |
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).
|
Nyelv: |
Angol |
|
Változat: |
19/04/2022 |
|
Fájlméret: |
1.1 MB |
|
Fájlnév: |
PU01447CEN_0222.pdf |
This technical paper studies the importance of scalability as a
competitive advantage in bioprocessing in the Life Science industry,
and Endress+Hauser's scalable Raman systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology and Liquid Analysis portfolio
(Liquiline CM44P, CM442 and OUSAF44, OUSBT66 and
Memosens CPS61E, CLS82E, COS81E, CLS82E).
|
Nyelv: |
Cseh |
|
Változat: |
06/09/2024 |
|
Fájlméret: |
381.4 KB |
|
Fájlnév: |
PU01584CEN_0124_cz_view.pdf |
A publication explaining how Raman data library software can be used
in cGxP environments for improved process control and regulatory
compliance.
|
Nyelv: |
Angol |
|
Változat: |
03/09/2025 |
|
Fájlméret: |
16.6 MB |
|
Fájlnév: |
PU01618CEN_0125.pdf |