Differential pressure
Deltabar PMD75

Deltabar PMD75 aluminum housing ©Endress+Hauser
Deltabar PMD75 stainless steel housing ©Endress+Hauser

Pressure measuring principle

Functional safety in process measurement

Deltabar PMD75 application ©Endress+Hauser
Deltabar PMD75 application ©Endress+Hauser
Deltabar PMD75 ©Endress+Hauser

Differential pressure transmitter with metal sensor for measurement of pressure differences

The Deltabar PMD75 differential pressure transmitter with with piezoresistive sensor and welded metallic membrane is used in all industries for continuous measurement in liquids, vapors and gases. The 3-key operation enables simple and reliable commissioning and operation. The integrated HistoROM data module allows easy management of process and device parameters. Designed according to IEC 61508 for use in SIL2/3 safety applications.

  • Előnyök

    • Best accuracy, reproducibility and long-term stability

    • Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508

    • Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION...

  • Alkalmazási terület

    For level, volume or mass measurement in liquids, differential pressure monitoring as well as flow measurement (volume or mass flow) in conjunction with primary elements in gases, vapors and liquids.

    • Process connections: Threads

    • Process temperature: -40...

Tulajdonságok és jellemzők

Vissza

Details

  • Mérési elv

    Differential pressure

  • Characteristic / Application

    Digital transmitter with metallic measuring diaphragms
    Modular transmitter
    Long term stability
    High static pressure/Overload resistance
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Supply / Communication

    4...20 mA HART:
    10,5...45V DC
    Ex ia: 10,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC

  • Accuracy

    Standard: 0.05%

    Platinum: up to 0.035%

  • Long term stability

    0,05% of URL/year

  • Ambient temperature

    -50 °C...85 °C
    (-58 °F...185 °F)

  • Process temperature

    -40 °C...85 °C
    (-40 °F...185 °F)

  • Process pressure absolute / max. overpressure limit

    420 bar (6300 psi)

  • Pressure measuring range

    10 mbar...250 bar
    (0.15 psi...3750 psi)

  • Main wetted parts

    Alloy C276
    316L
    Monel
    Tantalum

  • Process connection

    1/4-18NPT
    RC1/4"

  • Max. measurement distance

    400 m (1.312 ft) H2O

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN 10204-3.1

    NACE MR0175, MR0103

  • Marine approval

    GL/ ABS

  • Options

    HistoROM/M-Dat
    4-line digital display
    SS- or Aluminiumhousing
    Separate housing

  • Application limits

    Measuring cell:

    Metal welded

  • Mérési elv

    Differential pressure

  • Product headline

    Digital transmitter with metallic measuring diaphragms
    Modular transmitter
    Long-term stability
    High static pressure/Overload resistance
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Max. measurement error

    0,075%
    "PLATINUM" 0,05%

  • Max. process pressure

    max. 420 bar
    (max. 6 091 psi)

  • Medium temperature range

    Temperature gradient from pressure piping

  • Display/Operation

    Option

  • Outputs

    4...20mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Digital communication

    HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Hazardous area approvals

    ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS

  • Functional safety

    SIL

  • Material certificates

    NACE MR0103

    NACE MR0175

    EN10204-3.1

  • Mérési elv

    Differential pressure

  • Characteristic

    Digital transmitter with metallic measuring diaphragms
    Modular transmitter
    Long-term stability
    High static pressure/Overload resistance
    Secondary process barrier

  • Supply voltage

    4...20 mA HART

    10,5...45V DC (Non Ex):

    Ex ia: 10,5...30V DC

    PROFIBUS PA:

    9...32 V DC (Non Ex)

    FOUNDATION Fieldbus:

    9...32 V DC (Non Ex)

  • Reference Accuracy

    Standard: 0.05%

    Platinum: up to 0.035%

  • Long term stability

    0.03 % of URL/ year

    0.05 % of URL/ 5 years

    0.08 % of URL/ 10 years

  • Process temperature

    -40°C...85°C
    (-40°F...185°F)

  • Ambient temperature

    -50°C...85°C
    (-58°F...185°F)

  • Measuring cell

    10 mbar...250 bar
    (0.15 psi...3750 psi)

  • Smallest calibratable span

    1 mbar (0.015 psi)

  • Vacuum resistance

    50 mbar (0.73 psi)

  • Max. Turn down

    100:1

  • Max. overpressure limit

    On one side:

    420 bar

    (6300psi)

  • Process connection

    1/4-18NPT
    RC1/4"

  • Material process membrane

    316L, AlloyC,

    Tantal,

    Gold-Rhodium

  • Material gasket

    Viton, PTFE, EPDM, NBR

  • Fill fluid

    Silicone oil

    Inert oil

  • Material housing

    316L, Die-cast aluminum

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    WHG/ Overfill prevention
    SIL

  • Design approvals

    NACE MR0103
    EN10204-3.1

  • Marine approvals

    GL/ ABS

  • Specialities

    Diagnostic functions

  • Mérési elv

    Differential pressure

  • Product headline

    Digital transmitter with metallic measuring diaphragms
    Modular transmitter
    Long-term stability
    High static pressure/Overload resistance
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Max. measurement error

    0,075%
    "PLATINUM" 0,05%

  • Max. process pressure

    max. 420 bar
    (max. 6091 psi)

  • Medium temperature range

    Temperature gradient from pressure piping

  • Display/Operation

    Option

  • Outputs

    4...20mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Digital communication

    HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Hazardous area approvals

    ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS

  • Functional safety

    SIL

  • Material certificates

    NACE MR0103

    NACE MR0175

    EN10204-3.1

  • Mérési elv

    Differential pressure

  • Product headline

    Digital transmitter with metallic measuring diaphragms
    Modular transmitter
    Long-term stability
    High static pressure/Overload resistance
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Max. measurement error

    0,075%
    "PLATINUM" 0,05%

  • Max. process pressure

    max. 420 bar
    (max. 2175 psi)

  • Medium temperature range

    Temperature gradient from pressure piping

  • Display/Operation

    Option

  • Outputs

    4...20mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Digital communication

    HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Hazardous area approvals

    ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS

  • Functional safety

    SIL

  • Material certificates

    NACE MR0103

    NACE MR0175

    EN10204-3.1

Dokumentumok / Kézikönyvek / Szoftver

Tartozékok / alkatrészek

Nr
Order code
Specification
  • 13
    • Nr 13 Order code 52022418

      Push button housing, PA/FF

      Consists of: push button, cover + screws. Usage: external operation, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 13 Order code 52022419

      Push button housing, HART, version 1

      Consists of: push button, cover + screws. Colour light grey. Usage: external operation, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 13 Order code 52024110

      Push button housing, HART, version 2

      Consists of: push button, cover + screws. Colour dark grey. Usage: external operation, FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75.

  • 15
    • Order code 71111056

      Housing filter VA,EPDM,F15/31/T14/17,1pc

      Consists of: vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: housing T14, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Housing F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55. Housing F15 w/o B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

    • Order code 71219639

      Housing filter VA, VMQ, F15, T17, 1 pc.

      Consists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 bei B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

    • Order code 71043886

      Cable PE, L=2m/80inch, separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 71043888

      Cable PE, L=5m/200inch, separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 71043889

      Cable PE, L=10m/400inch,separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 71070738

      Cable FEP, L=5m/200inch,separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

  • 21
  • 20
    • Nr 20 Order code 52020432

      Cover T14/T15 Alu, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 52020433

      Cover T14/T15 Alu, Ex d, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 52028310

      Cover T14 316L, Ex d, EPDM

      Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 71002774

      Cover T17 316L, gasket

      Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 71002810

      Cover T17 316L, sight glass, gasket

      Material: 316L. Sight glass: mineral glass. Flat gasket EPDM, centering ring, screw. For approval 2,3,4,7,8,Q,W. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval BC,BD,IB. Usage: FMD71/FMD72.

    • Nr 20 Order code 71002811

      Cover T17 316L, sight glass PC, gasket

      Material: 316L. Sight glass: Polycarbonate PC. Flat gasket EPDM, centering ring, screw. For approval A,E,F,H,I,R,S,U,1,6. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval AA,BA,CA,CB,CC,CD,FA,FB, FD,IA. Usage: FMD71/FMD72.

    • Nr 20 Order code 71206965

      Cover T14 316L, Ex d, FVMQ

      Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.

    • Nr 20 Order code 71245247

      Cover T14/T15 Alu, sight glass, gasket

      Material: aluminium, coated. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 71245249

      Cover T14/T15 Alu,Exd,sight glass,gasket

      Material: aluminium. Sight glass mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 71245250

      Cover T14 316L, Ex d, sight glass, EPDM

      Material: 316L. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 25
    • Nr 25 Order code 52020432

      Cover T14/T15 Alu, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 25 Order code 52020433

      Cover T14/T15 Alu, Ex d, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 25 Order code 52028310

      Cover T14 316L, Ex d, EPDM

      Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 25 Order code 71002774

      Cover T17 316L, gasket

      Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 25 Order code 71206965

      Cover T14 316L, Ex d, FVMQ

      Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.

    • Nr 25 Order code 71206968

      Cover T14 316L, Ex d, sight glass, FVMQ

      Material: 316L. Sight glass: mineral glass,coated. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 21
    • Order code 71290825

      Ground terminal T14/T15/T17, F30/F31

      Consists of: spring washer, screw, earth handle, clamp. Usage: housing T14/T15/T17, FMB70, FMD71/FMD72/ FMD77/FMD78, PMC71, PMP71/PMP75, PMD70/PMD75. Housing F30/F31, FMB50/FMB51/FMB52/ FMB53, PMC51, PMD55, PMP51/PMP55.

  • 30
    • Nr 30 Order code 52024111

      Electronics HART Ex, ext. p. b., v2.0

      4-20mA, version 2.0. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 52024400

      Electronics HART Ex, v2.0

      4-20mA, version 2.0. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71026358

      Electronics HART Ex, v2.10

      4-20mA, version 02.10.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71026359

      Electronics HART Ex, ext. p. b., v2.10

      4-20mA, version 02.10.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071824

      Electronics PA, HW02.00, SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071825

      Electronics PA, ext. p.b., HW02.00,SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071826

      Electronics FF, HW2.00, SW3.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on electronics. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071827

      Electronics FF, ext. p.b., HW2.00,SW3.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on housing. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71196092

      Electronic HART Ex, v2.11

      4-20mA, version 02.11.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71196093

      Electronics HART Ex, ext. p. b., v2.11

      4-20mA, version 2.11.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71214057

      Electronics PA, Ex, HW2.00, SW3.00

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71214064

      Electronics PA, ext. p.b.,HW2.00, SW3.00

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71214066

      Electronics FF, ext. p.b.,HW2.00, SW2.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 02.00.zz. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71214069

      Electronics FF, HW2.00, SW2.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 02.00.zz. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71214890

      Electronics FF, ext. p.b.,HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.

    • Nr 30 Order code 71214892

      Electronics FF, HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.

    • Nr 30 Order code 71224775

      Electronics PA, HW02.00, SW4.01

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71224776

      Electronics PA, ext.p. b.,HW02.00,SW4.01

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71263933

      Electronics HART Ex, v2.20

      4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on electronics. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71263934

      Electronics HART Ex, ext. p. b., v2.20

      4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on housing. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71365258

      Electr.dp_m_g HART Ex, ext. p. b., v2.20

      4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on housing. Usage: PMD75 (dp mount gauge).

    • Nr 30 Order code 71365259

      Electronic dp_m_g HART Ex, v2.20

      4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on electronic. Usage: PMD75 (dp mount gauge).

    • Nr 30 Order code 71386147

      Elektronics HART Ex, v2.30

      4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on electronics. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71386153

      Electronics HART Ex, ext. p. b., v2.30

      4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on housing. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71386156

      Electronics dp HART Ex, ext. p.b., v2.30

      4-20mA. Software version 02.30.zz, HART 7 DevRev23. Push button on housing. Usage: PMD75 (gauge/absolute).

    • Nr 30 Order code 71386158

      Electronic dp HART Ex, v2.30

      4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on electronics. Usage: PMD75 (gauge/absolute).

  • 31
  • 35
  • 40
    • Nr 40 Order code 71002865

      Display module VU340, Cbar/Dbar/Dpilot S

      Digital display, 3 push buttons, snapped bracket. Languages DE/EN/FR/ES/IT/NL, from software version 02.00.zz; Usage: electronics HART. Languages DE/EN/FR/ES/IT/NL/JA/ZH. From software version 02.01.zz; Electronics HART. Languages DE/EN/FR/ES/IT/JA/ZH/RU, from software version 02.11.zz; Electronics HART. From software version 04.00.zz; Electronics PROFIBUS PA. From software version 03.00.zz; Electronics FOUNDATION Fieldbus, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75. From software version 01.00.zz; Electronics HART, FMD71/FMD72.

  • 55
  • 56
  • 57
  • 50