Analog chlorine dioxide sensor CCS50

CCS50: Analog chlorine dioxide sensor ©Endress+Hauser
CCS50 analog chlorine dioxide sensor with adapter for installation in CCA250 flow assembly ©Endress+Hauser

Sensor for water, process water and utilities in all industries

CCS50 is a robust, low-maintenance sensor for chlorine dioxide measurement. It provides stable and fast measured values in water, process water and utilities. The sensor ensures efficient disinfection even at minimum water volumes and helps to achieve highest water quality and safety, to avoid overdosing of chlorine dioxide or to ensure the absence of ClO2 in beverage plants and reverse osmosis. CCS50 ensures continuity for the installed base of analog chlorine dioxide measuring points.

  • Előnyök

    • Fast response time (t90 < 15 s) provides an accurate process view and enables prompt reaction to process changes as well as efficient process control.

    • Increased process safety: precise and long-term stable measurement ensures consistent process...

  • Alkalmazási terület

    CCS50 is an analog chlorine dioxide sensor for skid builders and end customers. It measures reliably in:

    • Drinking water - to ensure sufficient disinfection

    • Cooling systems or towers - to avoid pathogen growth

    • Wash water for packed vegetables and salads...

Tulajdonságok és jellemzők

Vissza

Details

  • Mérési elv

    Chlorine dioxide

  • Application

    Drinking water - to ensure reliable disinfection
    Cooling water - to avoid biofilm growth
    Food - to ensure food quality
    Utilities to secure the absence/presence of chlorine dioxide

  • Characteristic

    Amperometric measurement of dissolved chlorine dioxide

  • Measurement range

    Trace: 0 to 5 mg/l ClO2

    Standard: 0 to 20 mg/l ClO2

  • Measuring method

    - Closed, membrane covered measuring cell
    - Reduction of chlordioxide at the cathode

  • Design

    Closed amperometric 2-electrode measuring cell with PVDF membrane

  • Material

    Sensor shaft: PVC

    Membrane: PVDF

    Membrane cap: PVDF

  • Dimension

    Diameter: 25 mm (0.98 in)

    Length: 161 mm (6.34 in)

  • Process temperature

    +0 to 55 °C (32 to 130°F), non-freezing

  • Process pressure

    1 bar (14.5 psi)

  • Temperature sensor

    10k NTC

  • Connection

    analog with fixed cable

Dokumentumok / Kézikönyvek / Szoftver

Tartozékok / alkatrészek

Nr
Order code
Specification